261 research outputs found

    Multi-channel direct detection of light dark matter: theoretical framework

    Get PDF
    We present a unified theoretical framework for computing spin-independent direct detection rates via various channels relevant for sub-GeV dark matter — nuclear re- coils, electron transitions and single phonon excitations. Despite the very different physics involved, in each case the rate factorizes into the particle-level matrix element squared, and an integral over a target material- and channel-specific dynamic structure factor. We show how the dynamic structure factor can be derived in all three cases following the same procedure, and extend previous results in the literature in several aspects. For electron transitions, we incorporate directional dependence and point out anisotropic target materials with strong daily modulation in the scattering rate. For single phonon excitations, we present a new derivation of the rate formula from first principles for generic spin-independent couplings, and include the first calculation of phonon excitation through electron couplings. We also discuss the interplay between single phonon excitations and nuclear recoils, and clarify the role of Umklapp processes, which can dominate the single phonon production rate for dark matter heavier than an MeV. Our results highlight the complementarity between various search channels in probing different kinematic regimes of dark matter scattering, and provide a common reference to connect dark matter theories with ongoing and future direct detection experiments

    Multichannel direct detection of light dark matter: Target comparison

    Get PDF
    Direct-detection experiments for light dark matter are making enormous leaps in reaching previously unexplored model space. Several recent proposals rely on collective excitations, where the experimental sensitivity is highly dependent on detailed properties of the target material, well beyond just nucleus mass numbers as in conventional searches. It is thus important to optimize the target choice when considering which experiment to build. We carry out a comparative study of target materials across several detection channels, focusing on electron transitions and single (acoustic or optical) phonon excitations in crystals, as well as the traditional nuclear recoils. We compare materials currently in use in nuclear recoil experiments (Si, Ge, NaI, CsI, CaWO₄), a few of which have been proposed for light dark matter experiments (GaAs, Al₂O₃, diamond), as well as 16 other promising polar crystals across all detection channels. We find that target- and dark-matter-model-dependent reach is largely determined by a small number of material parameters: speed of sound, electronic band gap, mass number, Born effective charge, high-frequency dielectric constant, and optical phonon energies. We showcase, for each of the two benchmark models, an exemplary material that has a better reach than in any currently proposed experiment

    Multi-channel direct detection of light dark matter: theoretical framework

    Get PDF
    We present a unified theoretical framework for computing spin-independent direct detection rates via various channels relevant for sub-GeV dark matter — nuclear re- coils, electron transitions and single phonon excitations. Despite the very different physics involved, in each case the rate factorizes into the particle-level matrix element squared, and an integral over a target material- and channel-specific dynamic structure factor. We show how the dynamic structure factor can be derived in all three cases following the same procedure, and extend previous results in the literature in several aspects. For electron transitions, we incorporate directional dependence and point out anisotropic target materials with strong daily modulation in the scattering rate. For single phonon excitations, we present a new derivation of the rate formula from first principles for generic spin-independent couplings, and include the first calculation of phonon excitation through electron couplings. We also discuss the interplay between single phonon excitations and nuclear recoils, and clarify the role of Umklapp processes, which can dominate the single phonon production rate for dark matter heavier than an MeV. Our results highlight the complementarity between various search channels in probing different kinematic regimes of dark matter scattering, and provide a common reference to connect dark matter theories with ongoing and future direct detection experiments

    West Nile Virus Antibody Prevalence in Wild Mammals, Southern Wisconsin

    Get PDF
    Twenty percent prevalence of West Nile virus antibody was found in free-ranging medium-sized Wisconsin mammals. No significant differences were noted in antibody prevalence with regard to sex, age, month of collection, or species. Our results suggest a similar route of infection in these mammals

    Directional detection of light dark matter with polar materials

    Get PDF
    We consider the direct detection of dark matter (DM) with polar materials, where single production of optical or acoustic phonons gives an excellent reach to the scattering of sub-MeV DM for both scalar and vector mediators. Using density functional theory, we calculate the material-specific matrix elements, focusing on GaAs and sapphire, and show that DM scattering in an anisotropic crystal such as sapphire features a strong directional dependence. For example, for a DM candidate with mass 40 keV and relic abundance set by freeze-in, the daily modulation in the interaction rate can be established at 90% C.L. with a gram year of exposure. Nonthermal dark photon DM in the meV–eV mass range can also be effectively absorbed in polar materials

    A comparison of didodecyldimethylammonium bromide adsorbed at mica/water and silica/water interfaces using neutron reflection.

    Get PDF
    The layer structure of the dichain alkyl ammonium surfactant, didodecyldimethylammonium bromide (DDAB), adsorbed from water on to silica and mica surfaces has been determined using neutron reflection. Although sometimes considered interchangeable surfaces for study, we present evidence of significant differences in the adsorbed layer structure below the critical micelle concentration. A complete DDAB bilayer was assembled at the water/mica interface at concentrations below the critical micelle concentration (CMC). In contrast it is not until the CMC was reached that the complete bilayer structure formed on the oxidised silicon crystal. Removal of the complete bilayer on both surfaces was attempted by both washing and ion exchange yet the adsorbed structure proved tenacious.BPThis is the author accepted manuscript. The final version is available from Elsevier via http://dx.doi.org/10.1016/j.jcis.2016.06.01

    Real-world comparison of two molecular methods for detection of respiratory viruses

    Get PDF
    Background: Molecular polymerase chain reaction (PCR) based assays are increasingly used to diagnose viral respiratory infections and conduct epidemiology studies. Molecular assays have generally been evaluated by comparing them to conventional direct fluorescent antibody (DFA) or viral culture techniques, with few published direct comparisons between molecular methods or between institutions. We sought to perform a real-world comparison of two molecular respiratory viral diagnostic methods between two experienced respiratory virus research laboratories.Methods: We tested nasal and throat swab specimens obtained from 225 infants with respiratory illness for 11 common respiratory viruses using both a multiplex assay (Respiratory MultiCode-PLx Assay [RMA]) and individual real-time RT-PCR (RT-rtPCR).Results: Both assays detected viruses in more than 70% of specimens, but there was discordance. The RMA assay detected significantly more human metapneumovirus (HMPV) and respiratory syncytial virus (RSV), while RT-rtPCR detected significantly more influenza A. We speculated that primer differences accounted for these discrepancies and redesigned the primers and probes for influenza A in the RMA assay, and for HMPV and RSV in the RT-rtPCR assay. The tests were then repeated and again compared. The new primers led to improved detection of HMPV and RSV by RT-rtPCR assay, but the RMA assay remained similar in terms of influenza detection.Conclusions: Given the absence of a gold standard, clinical and research laboratories should regularly correlate the results of molecular assays with other PCR based assays, other laboratories, and with standard virologic methods to ensure consistency and accuracy
    corecore